Long-pulsed laser treatment is a skin laser treatment to treat Hypertrichosis, wrinkles, fine lines, and enlarged pores caused by photodamage, aging or other skin ailments. Long pulse lasers act on specific target tissues in the skin by emitting lasers of specific wavelengths.
The laser is emitted in millisecond pulses, much longer than most lasers with nanosecond pulses. This allows the laser to build up more energy between pulses and deliver more energy per pulse. The treatment principles include the following aspects:
1. Selective photothermal effect: The laser energy is absorbed by specific pigments (such as melanin) or hemoglobin in the skin and converted into heat energy, thereby destroying the target tissue.
2. Stimulating collagen proliferation: Long pulse lasers can penetrate deep into the dermis, stimulate fibroblast proliferation, and promote collagen production, thereby improving the elasticity and firmness of the skin.
3. Thermal effect: By controlling the pulse width and energy of the laser, the target tissue can be precisely heated to reduce damage to surrounding healthy tissues.
Long pulse lasers are widely used in medical cosmetology, mainly in the following aspects:
1. Germany imported quartz optical fiber
Ø1.2mm@1064nm / Ø1.5mm@755nm (optional). Equipped with high safety measures: the handle features a built-in fibre optic insertion position detector.
2. 6 Spot Sizes
Multiple spot sizes translate to fewer required laser pulses, resulting in increased treatment speeds and greater overall patient comfort.
• 1064nm: 7.5mm, 9.5mm, 11mm, 12mm, 14mm, 16mm
• 755nm: 8mm, 10mm, 12mm, 14mm, 18mm, 20mm
3. Comfortable treatments
Incorporates 2 cooling methodologies:
• Air cooling (no consumable requirements)
• Liquid nitrogen cooling
7. Dual Wavelength Treatment Capabilities: Both 755 nm and 1064 nm wavelengths are available, allowing you to treat a wide range of indications across multiple skin types, going far beyond standard hair removal applications.
| Attention / Guidelines | |
|---|---|
| Avoid Contamination | Remove the dust cap before inserting the optical fibre into the laser mount and secure it quickly. Replace the dust cap immediately upon removal, completing both actions within 10 seconds to prevent contamination. |
| Avoid Knocking | Install the optical fibre carefully according to technical specifications to prevent structural damage. Store the device properly when not in use. |
| Avoid Bending | Maintain bending radii over 120mm for 1.2mm core fibers and over 150mm for 1.5mm core fibers. Avoid forceful pulling or bending. |
| Parameter | 1064nm Model | 755nm Model | 1064nm + 755nm Dual Model |
|---|---|---|---|
| Wavelength | 1064nm | 755nm | 1064nm + 755nm |
| Aiming Light | Green | Red | Green + Red |
| Xenon Lamp Quantity | 2 | 2 | 4 |
| Xenon Lamp Size | Φ10 130mm | ||
| Laser Rods Quantity | 1 | 1 | 2 |
| Laser Rods Size | Φ8 130mm | ||
| Fiber Core | φ1.2mm | φ1.5mm | φ1.5mm |
| Security Measures | Supports fiber plug and removal detector | ||
| Spot Size (Small) | 7.5 / 9.5 / 11.5mm | 8.0 / 10.0 / 12.0mm | |
| Spot Size (Big) | 12.0 / 14.0 / 16.0mm | 14.0 / 18.0 / 20.0mm | |
| Pulse Duration | 0.3 - 100ms | ||
| Frequency | 0.3 - 10Hz | ||
| Screen Size | 10.1 inch display interface | ||
| Box Dimensions | 1020mm * 1000mm * 710mm | ||
| Weight | 145 Kg | ||